Shell and Tube Heat Exchanger Start-up and Shutdown Procedures




  

Shell and tube heat exchangers are designed to eliminate problems from differential thermal expansion of the shell and the tubes.  When the temperature difference between the hot fluid and the cold fluid is large, a removable bundle or a floating head is used to avoid damage from the different thermal expansion rates of the tubes and the shell.
  
For extreme temperature differentials, the metal temperatures should be analyzed carefully.  Mechanical stress calculations should be performed to determine the consequences of any thermal shock on the heat exchanger.
    
In some cases, differential thermal expansion can be a problem at start-up or shutdown.  Many shell and tube heat exchangers have suffered damage during start-up and shutdown because the fluids were not introduced or removed in the proper sequence.
  
The table below offers suggestions on the order in which the hot and cold fluids should be introduced at start-up or removed at shutdown for different applications.
       
Exchanger
Type
Fluid Location 
Start-up Procedure
Shut-down Procedure
Shell Side
Tube Side
Fixed
Tubesheets
Liquid - HOTLiquid - COLDStart both fluids gradually at the same timeShut down both fluids gradually at the same time
Condensing gas - HOTLiquid or Gas - COLDStart hot fluid first, then slowly start the cold fluid.  Avoid temperature shockShut down cold fluid first, then hot fluid
Gas - HOTLiquid - COLDStart hot fluid first, then cold fluidShut down cold fluid gradually, then hot fluid
Liquid - COLDLiquid - HOTStart both fluids gradually at the same timeShut down both fluids gradually at the same time
Liquid - COLDGas - HOTStart cold fluid first, then hot fluidShut down hot fluid first, then cold fluid
Removable Bundle

u-tubes
floating head
Liquid - HOTLiquid - COLDStart hot fluid first, then cold fluid graduallyShut down hot fluid first, then cold fluid
Condensing gas - HOTLiquid or Gas - COLDStart hot fluid first, then cold fluid graduallyShut down hot fluid first, then cold fluid gradually
Gas - HOTLiquid - COLDStart hot fluid first, then cold fluid graduallyShut down hot fluid first, then cold fluid
Liquid - COLDLiquid - HOTStart cold fluid first, then hot fluid graduallyShut down hot fluid first, then cold fluid
Liquid - COLDGas - HOTStart cold fluid first, then hot fluid graduallyShut down hot fluid first, then cold fluid

Commenti

  1. T.S. Industrial Corporation Limited focuse on varies finned tube and close work with heat exchanger and boiler industrial manufacturer. www.lordfintube.com

    RispondiElimina
  2. Gireesh Heat Exchanger Manufacturer in Coimbatore & Cooling Towers is established in the year 1998 at Coimbatore, Tamil Nadu. We are one amongst the leading manufacturers and Exporters in Coimbatore .
    Visit Website:
    http://www.gireeshheatexchangers.com/

    RispondiElimina
  3. Thanks for sharing this article here. I appreciate this article for its well-researched content and excellent wording. 316 Stainless Steel Bolts Suppliers

    RispondiElimina
  4. There are many blogs I have read. But when I read Your Blogs I have found such useful information, fresh content with such amazing editing everything is superb in your blog. we also provide various types of fasteners such as 904l Stainless Steel Flanges.

    RispondiElimina
  5. Thanks for sharing this informative post. When I read your post I understood the correct use of different types of fasteners. If anyone is looking for high-quality UNS S30400 Fasteners, you can visit this official site Shree Ashapura Steel Centre.

    RispondiElimina
  6. The article was concise and efficiently explained the facts. Thank you for the great and interesting content, blog writer. Visit 304 Stainless Steel Strips.

    RispondiElimina
  7. Questo commento è stato eliminato dall'autore.

    RispondiElimina

Posta un commento

Post più popolari